Speak To An Expert

(877) 582-9899

Mixing and Odor Control for Wet Wells

TITUS Twister Mixing Aerator

The patented TITUS Twister mixing aerator keeps wet wells and lift stations fully mixed and aerated, controlling FOG, odor, and corrosion with no moving parts in the water.

What It Does

Aeration and Mixing for Wet Wells and Lift Stations

The TITUS Twister Mixing Aerator is built to solve the most common collection-system problems: fats, oils, and grease (FOG), hydrogen sulfide odor, corrosion, and blockages. It delivers strong aeration and mixing across pump stations, lift stations, and wet wells in municipal, industrial, and commercial systems.

Twisters are available throughout North America through the industry leaders in our Distributor Network.

The patented TITUS Twister mixing aerators are made in the USA, proudly produced by Titus Wastewater Solutions at our facility in Casper, Wyoming.

The Challenges

Wastewater agencies face mounting challenges in maintaining collection systems. Hydrogen sulfide (H₂S), acids, and other byproducts from municipal and industrial sources generate odor, safety risks, and corrosion.

Physical debris compounds the issue. Fats, oils, grease (FOG), and inorganic solids contribute to blockages, while wipes and non-dispersibles form “mop heads” that clog pumps and cause lift station failures. Pharmaceuticals and pathogens further impact system health.

Discharges from breweries, restaurants, and industrial facilities continue to overwhelm infrastructure, demanding stronger, more resilient solutions.

The Solution

The TITUS Twister mixing aerator combines Air Lift Technology with a stainless steel manifold and base assembly, a perforated rubber membrane diffuser, purpose-built HDPE blades, durable blowers, and a protective cabinet enclosure.

It delivers high-efficiency mixing and aerobic conditioning while preventing pump air-lock and cavitation. Unlike grinders that shred wipes and rags into smaller particles that pass through to the plant, the Twister keeps that debris intact and moving so it can be screened and removed at the treatment facility. The result is less clogging, lower maintenance, and relief from one of the most common pain points in wastewater systems.

Tougher mixing, fewer callouts, longer pump life. See what the TITUS Twister can do for your system.

LET’S TALK ABOUT SOLVING YOUR PROBLEMS

See How It Works

Applications

Field-Tested Applications Across the Industry

Where it’s used:

What it controls:

  • FOG (fats, oils, and grease)
  • Odor and corrosion
  • Disinfection
  • Stormwater applications

Advantages

Built-In Benefits for Long-Term Wastewater Success

  • Addresses fats, oils, and grease at the source
  • Reduces odor and prevents corrosion
  • Keeps solids suspended
  • Transfers dissolved oxygen efficiently
  • Extends the life of pumps and equipment
  • Easy to maintain, which lowers operating costs
  • Built with high-quality components
  • Optional Ozone Enhanced systems for heavy FOG and odor

Diffused Air Only, Fiberglass Enclosure, 2hp Blower

  • FOG & Odor Control
  • 8’Ø Area of Influence
  • Minimum Operating Level 2’-0”
  • Maximum Operating Level 5’-0”

Diffused Air Only, Aluminium Enclosure, 2hp Blower

  • FOG & Odor Control
  • 8’Ø Area of Influence
  • Minimum Operating Level 2’-0”
  • Maximum Operating Level 7’-0”

Diffused Air Only, Aluminium Enclosure, 3hp Blower

  • FOG & Odor Control
  • 12’Ø Area of Influence
  • Minimum Operating Level 3’-0”
  • Maximum Operating Level 8’-0”

Ozone Enhanced System: TT20, 3hp Blower & Stainless Steel Enclosure

  • Advanced FOG & Odor Control
  • 12’Ø Area of Influence
  • Minimum Operating Level 3’-0”
  • Maximum Operating Level 5’-0”

Ozone Enhanced System: TT40, 6.2hp Blower & Stainless Steel Enclosure

  • Advanced FOG & Odor Control
  • 12’Ø Area of Influence
  • Minimum Operating Level 3’-0”
  • Maximum Operating Level 11’-0”

Not Sure Which Twister Model is Right for You?

Product Resources

TITUS Twister Mixing Aerator Brochure (pdf)

TWISTER Specification (pdf)

Twister Sizing and Quote Request (pdf)

Definitive Guide to Understanding Ozone (pdf)

Customer Testimonial (Bozeman, MT) (pdf)

Frequently Asked Questions

What is a wastewater mixing aerator?

A wastewater mixing aerator keeps a wet well or lift station fully mixed and aerated so solids stay suspended and odor-causing buildup never develops. The TITUS Twister does this with Air Lift Technology: a shore-side blower feeds a submerged diffuser, driving strong circulation with no moving parts in the water.

In lift stations and pump stations, the Twister targets four costly problems: fats, oils, and grease (FOG), hydrogen sulfide odor and corrosion, blockages from wipes and rags, and pump air-lock. It handles all four at the source by keeping the well aerobic and in constant motion.

The difference is where the water sits. The Mixing Aerator is built for confined collection-system structures like wet wells, lift stations, and pretreatment manholes. The Twister-FL Floating is built for open surface water like lagoons and ponds. If your problem is in the collection system, choose the Mixing Aerator.

No. The blower and controls sit shore-side in a protective cabinet, and the only submerged parts are the manifold and diffuser, so there are no in-water electrical components to service. Maintenance is minimal, and the air-driven design means fewer service interruptions and longer pump life.

Yes. Because the blower and controls sit shore-side and only the manifold and diffuser go in the water, the Twister installs into existing wet wells without in-water electrical, which keeps install cost and downtime low.

Sizing comes down to two factors: your operating depth and the area you need kept in motion. Twister models cover an 8 to 12 foot diameter area of influence at depths from 2 to 11 feet. Use the model selector above or request a sizing review for a site-specific match.

The Ozone Enhanced models, TT20 and TT40, inject ozone into the same mixing process for advanced FOG and odor control. They are the step up for sites where standard diffused air alone is not keeping pace with heavy grease or persistent odor.

Yes. The patented Twister mixing aerators are made in the USA at the Titus Wastewater Solutions facility in Casper, Wyoming, and are engineered to meet Build America, Buy America (BABA) requirements for federally funded wastewater projects.

Upgrade Your Wastewater Mixing and Odor Control

Looking for a smarter, low-maintenance solution to wastewater mixing? Get in touch today to see how the TITUS Twister controls FOG and odor, keeps solids suspended, and extends the life of your pumps.